UVCify

UVCify Reports

UV-C sizing reports your clients can verify

Size lamps for HVAC coils and food-industry rooms, see the irradiance map for free, and order a report with your company on it.

  • Free preview, no card
  • 114 lamp models
  • QR check on every report
A sample HVAC coil project in UVCify, with its report delivered
Projects / Sample Company / Hospital
HVAC coilUVC-2026-SAMPLE

Hospital | AHU-01

Status
Delivered
Lamps
4 × Signify (Philips) TUV 36T5 HO 4P SE
Prepared by
Sample Company
ResultsLamp layoutGraphsHow reports are verified
Sample: Coil Surface Irradiation Intensity
Coil irradiance min / mean / max
903 / 1,863 / 2,771 µW/cm²
Disinfection time min / mean / max
2.41 / 3.97 / 7.38 min
Target
Aspergillus niger (spores), 99.99 % (400 mJ/cm²)

Lamp data in the calculator, from the manufacturers’ own datasheets

  • Signify (Philips)48 lamps
  • Light Sources Inc.27 lamps
  • LEDVANCE (OSRAM)23 lamps
  • UVC Spectrum16 lamps

Coil disinfection for HVAC companies

  • — Serpentine and fin-tube cooling coils
  • — Coil front and side views with lamp positions
  • — Coil surface irradiation and disinfection-time maps
  • — Airstream single-pass inactivation and lamp-count analysis
Open calculator →

Room disinfection for the food industry

  • — Processing rooms, cold stores, packaging areas
  • — Room plan and elevation with fixtures
  • — Work-surface irradiation and disinfection-time maps
  • — Occupant safety at eye level and air changes
Open calculator →

For the building owner and auditor

A report the next person can verify.

Every report is issued for one company, project and unit. A QR code on the report opens a public page that confirms it is genuine, so nobody has to take the numbers on trust.

What the verification page shows

Genuine report

Report no.
UVC-2026-SAMPLE
Company
Sample Company
Site
Hospital
AHU name
AHU-01

How it works

  1. Enter the coil or room

    Pick the lamp by manufacturer and model. Its size and UV-C output fill in automatically.

  2. See the result for free

    Lamp layout, irradiation map and disinfection times update as you type.

  3. Order the report

    Pay per report or use your monthly plan. The PDF carries your company, the client and a QR check.

Simple pricing

Previews are free. Pay per report, save on bulk uploads, or take Business if you size UV-C every week. Try Business free for 14 days.

See pricing
Basic
$29
per report, $19 each in bulk
Business
$99/mo
10 reports a month, extended analysis in every report

Guides to UV-C disinfection

All articles →

Questions

How are the calculations made?

Each lamp is modelled as a linear source and checked against the manufacturers' own published irradiance values. Reflections, lamp aging, cold-air and fouling losses are included. Dose is converted to inactivation with first-order kinetics and published UV-C susceptibility (D90) data. Every report lists the method and assumptions.

Which lamps can I choose?

Standard, high-output and amalgam lamps from Signify (Philips), LEDVANCE (OSRAM), Light Sources and more. Pick the manufacturer and model, and the type, size and UV-C output are filled in automatically.

Can a report be reused for another AHU?

No. Every report is issued for one company, project and AHU or room. These are watermarked into every graph and can be checked through the QR code on the report.

Can I calculate many air handlers at once?

Yes. Upload one Excel file with a row per AHU or room to calculate them all at once. On the Business plan you can also order all the reports in one go.